The passive house institute has designed a scale arrow for your use during your. The passive house institute has designed a scale arrow for your use during your visits to the building site as an aid to point to the critical spot and provide a reference in photographs for quality assurance and documentation. Prevention of errors due to thorough external checking of planning prior to the start of construction. New passive house software available for free builder. Phius certified over 98% of all north american passive house projects in 2017 and 100% of those projects used phiustrained professionals. The process for passive house building certification. This test is one of the few possibilities for testing the quality of construction work in. A list of certified passive house designersconsultants can be found here. Wolfgang feist in germany to develop the passive house concept incorporated in the first passive houses built in 1990 with research, development of the passive house planning package phpp energy modeling software program, training and certification of passive house consultants and buildings, and testing and.
Detailed testing protocols available to manufacturers on request mailat. Once you have acquired a main passive house tradesperson, consultant or designer certificate, you can earn additional seals by gaining ex. How to build a passive house with insulated concrete forms. For a building to be considered a passive house, it must meet the following criteria for detailed criteria, please see the building certification section. A guide listing all the requirements for testing and measuring airtightness in nz, to comply with asnzs iso 9972. It is delivered by a certified trainer from the university of strathclyde energy systems research unit the bre centre of excellence in energy utilisation in partnership with the bre academy. No part of this course may be reproduced or translated, stored in a retrieval system or transmitted, in any form or by any means, electronic, recording or otherwise, without the prior written permission of passive house institute phi. A typical passive house has a reduced energy consumption of 8090% over a building built to code, and offers an attractive, costeffective path toward earth advantage net zero or net zero ready certification. Compact heat pump units ventilation systems capacity 600 m 3 h decentralised ventilation system single room only with second room connection. House institute phi requires for new building passive house certification. Cphc is the only professional passive building program that includes instruction in energy modeling software. As an independent authority, the passive house institute tests and certifies products in respect of their suitability for use in passive houses. From 2021, all new buildings must meet the provisions of the nearly. It gives participants the tools required to write a successful test.
The passive house institute us phius has released an updated and improved version of wufi passive 3. Building certification is a stamp of quality assurance that a building meets the high performance and comfort levels of the passive house standard. Passive house standard criteria for the passive house, enerphit and phi low energy building standard, version 9f ip, revised 12. The specific space heat demand modeled by a certified passive house consultant must be less than or equal to 10kbtusq.
Passive testing is a software testing technique that observes the system without interaction. Certified european passive house designer bre academy. International passive house association guidelines. An extremely accurate, excelbased energy balance tool, the phpp not only determines the space heating and primary. Passivhaus buildings provide a high level of occupant comfort while using very little energy for heating and cooling. Passive house owns and operates a modern minneapolis blower door with full digital pressure set and laptop system software for recording and analysing test results. Certified passive house verification using the passive house planning package can also be submitted for various subsidy programmes. This test is one of the few possibilities for testing the quality. The testing method compared the results of the phpp with those of three other reference tools by simulating 38 test cases, 21 for heating and 17 for cooling. Any leaks remaining in the building envelope can be detected with this test and remedied if necessary. In january 2019, the passive house planning package phpp version 9. Passive house tool phpp validated by ansiashrae standard 140.
To start the certification process you will need to engage a certifier approved by the passive house institute, ideally at the start of a project. The modified temperature profile can be used to test a buildings summer. House district of bahnstadt in heidelberg germany has passed the test. The technical criteria for building a passive home. It is the only passive building certification that combines a thorough passive house design verification protocol with a stringent quality assurancequality control.
Requirements and testing procedures for singleroom ventilation pdf 207 kb. Password testing is performed to check if the user can login using easy passwords. By downloading and using the images, software and tools, you acknowledge these. The passive house institute new zealand phinz is an incorporated charitable trust. The phpp allows users to create a complete building model to determine the energy performance of both the whole building and its individual elements. Phpp and designph software for passive house design. The passive house standard uses a different method to measure the airtightness of a building. Certified passive house designers must not be confused with accredited building certifiers who carry out certification of buildings as certified passive houses. Course outlines passive house canada maison passive canada. Trainees receive a free 8week license to the wufi passive software. The passive house institute has provided comprehensive support throughout the. The passive house institute is developing and improving upon algorithms and software tools for dynamic building simulations, the determination of energy. Blower door protocol for passive house certification 475 high. They are built with meticulous attention to detail and rigorous design and construction according to principles developed by the passivhaus institute in germany, and can be certified through an exacting quality assurance process.
Cphcs are listed in the phius cphc database and join a robust community of passive building practitioners across north america. The passive house institute phi is an independent research institute that has played an especially crucial role in the development of the passive house concept the only internationally recognised, performancebased energy standard in construction. Airtightness testing explained passive house systems. Picture component name manufacturer country air flow range from m 3 h to m 3 h heat recovery rate specific electric powerwhm 3. It is an essential part of the building design process. Criteria for passive house component certification. Drain water heat recovery pdf 189 kb warm water heat recovery. Blower door protocol for passive house certification automated blowerdoor test.
P assive house institute the passive house institute phi is an. Automated blowerdoor test according to en829 with dg700 manometer controlled by laptop. You can find more information regarding certified passive house designersconsultants here. The course prepares you for the passive house exam which is set by the passive house institute. The passive house institute is constantly developing and improving upon algorithms and software tools for dynamic building simulations, the determination of energy balances and the planning of passive house buildings for example, through the passive house planning package. The passive house district of bahnstadt in heidelberg germany has passed the test. On passipedia, basic passive house information and insights are available for all to see, whereas members of the international passive house association ipha receive special access to. Calculation sheets for space heating balances annual and monthly methods, and for heat distribution and supply as well as for the electricity and primary energy demand, constitute the main features of this tool.
Passive house is a building standard that is truly energy efficient, comfortable and affordable at the same time passive house is not a brand name, but a tried and true construction concept that can be applied by anyone, anywhere. On the other hand, active testing involves interaction with the system. When it comes to the technical criteria required to be considered a passive house in north america, these standards are set by the passive house institute us phius and by passive house canada. Phius building certification program does not require the use of windows, doors, or skylights for which performance data has been verified through the verified window performance data program. This course provides an overview of the core principles of passive house. Criteria for the passive house, enerphit and phi low energy. Criteria for the passive house, enerphit and phi low. Passive house tool phpp validated by ansiashrae standard. Blower door protocol for passive house certification 475. Jun 14, 2018 the passive house standard uses a different method to measure the airtightness of a building.
The passive house institute has developed a flexible system to promote lifelong learning and the gradual acquisition of passive house knowledge. According to the passive house institute us phius, homes built to passive standards use 50% to 70% less energy than typical houses. Our mission is to increase the awareness of the benefits and opportunities of highperformance buildings based on the passive house standard, through research, education and building industry engagement. The space heating energy demand is not to exceed 15 kwh per square meter of net living space treated floor area per year or 10 w per square meter peak demand in climates where active cooling is needed. Passipedia constitutes a vast array of cutting edge, scientifically sound, passive house relevant articles.
The institute acts as an independent testing and certification centre. The passive house planning package phpp is the building energy modelling software used to design passive house buildings and it is an essential part of the building design process. The test results generally agreed very well with those of the reference software and the acceptance range suggested by the testing method and confirmed the. For a building to be considered a passive house, it must meet the following criteria for detailed criteria, please see the building certification section 1. In order to check the airtightness of a building, it is useful and advisable to carry out an airtightness measurement known as the blowerdoor test. Professional certifications from the passive house institute us. The onsite inspections and testing help to assure phius and the project teams that the buildings will perform as designed. Get a clear overview of the passive house standard, certification requirements and the various elements to consider when designing and constructing passive house buildings. Results from modelling different test cases with the software being tested are. The passive house institute us offers various professional certifications focusing. The passive house institute phi has introduced efficiency classes for windows and other transparent building components in order to help set highly energy efficient products apart at a glance.
A clear classification is not always easy due to the diverse educational qualifications, professions and the legal provisions relating to buildings worldwide. With the phpp you can create a complete building model and use it to determine the energy performance of both the whole building and its individual elements. Passivhaus institut phi an independent research institute formed in 1996 by dr. Passive house or passivhaus meaning passive building in german is a certified building system developed in darmstadt, germany and administered by the passive house institute.
The institute acts as an independent testing and certification centre for buildings and building components such as wall and construction systems, windows, doors, connections, ventilation systems and compact systems. Certified products have been tested according to uniform criteria. For more detailed information on phpp visit the passivhaus institute website. The passive house institute is currently developing a more detailed shading analysis for. The passive house institute developed the passive house planning package phpp to help designers in just this regard. In order to reach the passive house standard, all components must be optimised and checked for compatibility. For this reason, the passive house institute has specified two possibilities for classification as a certified passive house designer. Phi has played an especially crucial role in the development of the passive house concept. The phpp is a software programme created by the passive house institute. P assive house institute the passive house institute phi is an independent research institute lead by dr wolfgang feist with a continuously growing interdisciplinary team of employees. I was extremely impressed by the quality of the curriculum and the expert knowledge of the instructor. Blower door testing is essential to verify air tightness in construction.
In addition, the iac, comprising leading high performance building manufacturers, facilitate and shape critical research, gain market intelligence, speed innovation, and expand the highperf. The passive house is the building standard of the future for many years passive houses have proved successful both as new constructions and as refurbishments. Test report most testing software will prepare reports that contain most of this. The passive house planning package phpp is the building energy modelling software used to design a passive house building. The passive house institute phi is an independent research institute that. These extreme energy savings can be achieved through super insulation, very limited infiltration, thermal bridge free construction techniques, and heat recovery ventilation. Massachusetts stretch energy code will include a passive house compliance alternative passive house institute phi or passive house institute us phius. Where q50 is an expression of the amount of air leakage in relation to the total exposed surface used for tgd. Blower door protocol for passive house certification. The passive house institute phi is an independent research institute that has played an especially crucial role. Institute contracted remi charron consulting services, to test phpp version 9. Wufi passive, which combines passive building energy modeling with dynamic.
Building component availability in the north american market. The phi actively develops building science methodologies and testing to quantify and verify the performance of buildings in all climate conditions and programs. A search for other certified passive house designersconsultants can be carried out using the search function for members of the ipha the international passive house association. Passive house online training passive house institute. Bim2ph is the new bim tool developed by the passive house institute, which aims to allow data entry in 3d bim software and transfer information for the energy balance calculation and efficiency design into the passive house planning package phpp. The efficiency classes are based on heat losses through the frame and glass edge of the window. Passive house planning package a tried and tested planning tool the phpp based on excel was introduced for the first time in 1998 and has been continually further developed ever since. L, n50 used for passive house standard is how the air permeability rate is expressed in air changes per hour ach. We have been involved with a number of developers who have been trying to build housed that score below. The passive house institute phi is an independent research institute that has played an especially crucial role in the development of the passive house concept the only internationally. The validation tests consist of a series of carefully described sample case building plans. Statement to the correct interpretation of the certificates for ventilation units issued by the passive house institute.
The passive house planning package phpp is available for purchase here by downloading and using the images, software and tools, you acknowledge these terms and conditions. Login phius staff and phius certified professionals. Passive house institute phi the validation tests consist of a series of carefully described sample case building plans. Passive house plus is an awardwinning magazine focused on energy efficient, healthy, sustainable buildings, based on the passive house or passivhaus standard. Apr 18, 2020 passive house school is an online platform to help you design passive house buildings through trainings, online courses, consulting and certification. Passive house planning package phpp passivhaus institut. By taking this course you can start to prepare for the international certified passive house designer exam or better follow along a phppdesignph workshop. Aug 15, 20 those differences have contributed to a twoyear stalemate between the german and american passive house institutes, which have stopped collaborating on software, testing and certification. They are not part of the passivhaus accreditation scheme but are attempting to build ultralow energy buildings with a target of achieving an a rating on their epc.